Micro-Bath thermometer calibrators |
Model |
Range |
Accuracy |
Description/Features |
6102
Micro-Bath |
35 °C to 200 °C
95 °F to 392 °F |
±0.25 °C |
Worlds smallest calibration bath.
Stability to ±0.02 °C.
Stirred 2.5-inch-diameter tank. |
7102
Micro-Bath |
5 °C to 125 °C
23 °F to 257 °F |
±0.25 °C |
Portable bath to 5 °C.
No refrigerationsolid-state cooling.
Stability to ±0.015 °C. |
7103
Micro-Bath |
30 °C to 125 °C
22 °F to 257 °F |
±0.25 °C |
Ultracold Micro-Bath reaches 30 °C.
No refrigeration or external cooling needed.
Stability to ±0.03 °C. |
Handheld dry-well thermometer calibrators |
Model |
Range |
Accuracy |
Description/Features |
9100S
Handheld
Dry-Well |
35 °C to 375 °C
95 °F to 707 °F |
±0.25 °C at 100 °C
±0.5 °C at 375 °C |
Worlds smallest dry-well.
Fixed block with 4-inch well depth.
Four hole patterns available. |
9102S
Handheld
Dry-Well |
10 °C to 122 °C
14 °F to 252 °F |
±0.25 °C |
Handheld unit cools to 10 °C.
Two 0.5-inch-diameter, removable sleeves. |
Field dry-well thermometer calibrators |
Model |
Range |
Accuracy |
Description/Features |
9009
Dual-Block Calibrator |
15 °C to 350 °C
5 °F to 662 °F |
Cold block: ±0.2 °C
Hot block: ±0.6 °C |
Dual-block industrial dry-well.
Each block has two wells with removable sleeves.
Water- and air-tight enclosure. |
9103
Field Dry-Well |
25 °C to 140 °C
13 °F to 284 °F |
±0.25 °C |
Small, lightweight field calibrator reaches 25 °C.
Stability to ±0.02 °C.
Calibrates up to six probes at once. |
9140
Field Dry-Well |
35 °C to 350 °C
95 °F to 662 °F |
±0.5 °C |
Portable field calibrator.
Choose from four multi-hole, removable inserts. |
9141
Field Dry-Well |
50 °C to 650 °C
122 °F to 1202 °F |
±0.5 °C to 400 °C
±1 °C to 650 °C |
High-temp field calibrator.
Interface-it software and RS-232 included.
Extremely small and fast for temperature range. |
3125
Surface Calibrator |
35 °C to 400 °C
95 °F to 752 °F |
±0.5 °C to 200 °C
±1.0 °C to 400 °C |
Calibrates surface sensors.
Plate stability of ±0.3 °C. |
Infrared calibrators |
NEW! Precision Infrared Calibrators |
Model |
Range |
Accuracy |
Description/Features |
| 4180 |
–15 °C to 120 °C |
± 0.40 °C at –15 °C
± 0.40 °C at 0 °C
± 0.50 °C at 50 °C
± 0.50 °C at 100 °C
± 0.55 °C at 120 °C |
Fast, portable and easy to use
Correct target size for most thermometers
Calibration solutions from –15 °C to 500 °C (5 °F to 932 °F)
Radiometrically calibrated for traceable and consistent results |
| 4181 |
35 °C to 500 °C |
± 0.35 °C at 35 °C
± 0.50 °C at 100 °C
± 0.70 °C at 200 °C
± 1.20 °C at 350 °C
± 1.60 °C at 500 °C |
Model |
Range |
Accuracy |
Description/Features |
9132 |
50 °C to 500 °C
122 °F to 932 °F |
±0.5 °C at 100 °C
±0.8 °C at 500 °C |
Certifies most handheld pyrometers.
Short heating and cooling times. |
9133 |
30 °C to 150 °C
22 °F to 302 °F |
±0.4 °C |
Calibrates at cold temperatures.
Gets to desired temperature quickly. |
9135
3-Pt. IR Calibrator |
50 °C, 100 °C, 150 °C
122 °F, 212 °F, 302 °F |
±1 °C |
Easiest to use IR calibrator.
Three set-pointsall reached quickly. |
Metrology Well high accuracy temperature and thermometer calibrators |
Model |
Range |
Accuracy |
Description/Features |
9170 |
45 °C to 140 °C
(49 °F to 284 °F) |
±0.1 °C |
Best-performing industrial heat sources (accuracy, stability, uniformity)
in the world.
Immersion depth to 203 mm (8 in).
Optional ITS-90 reference input reads PRTs to ±0.006 °C.
Temperature range from 45 °C to 700 °C. |
9171 |
30 °C to 155 °C
(22 °F to 311 °F) |
±0.1 °C |
9172 |
35 °C to 425 °C
(95 °F to 797 °F) |
±0.1 °C at 100 °C
±0.15 °C at 225 °C
±0.2 °C at 425 °C |
9173 |
50 °C to 700 °C
(122 °F to 1292 °F) |
±0.2 °C at 425 °C
±0.25 °C at 660 °C |
Zero point dry-well |
Model |
Range |
Stability |
Description/Features |
9101 |
0 °C
32 °F |
±0.05 °C |
Solid-state cooling.
Replaces messy ice bathseasy to operate.
Three wells, each 6 inches deep. |
Dual block dry-well |
Model |
Range |
Stability |
Description/Features |
9011
Hot Block |
50 °C to 670 °C
122 °F to 1238 °F |
±0.15 °C at 100 °C
±0.65 °C at 600 °C |
Combined ranges from 30 °C to 670 °C.
1 unit 2 blocks.
Two independent temperature controllers (hot and cold side).
Stability: ±0.01 °C.
Multi-hole inserts hold up to 8 probes at once. |
Cold Block |
30 °C to 140 °C
22 °F to 284 °F |
±0.25 °C (insert wells)
±0.65 °c (fixed wells) |
Portable lab dry-wells |
Model |
Range |
Stability |
Description/Features |
9007 |
40 °C to 140 °C
40 °F to 284 °F |
±0.15 °C |
40 °C with solid-state Peltier cooling.
Rugged truck-, plane-, and sea-worthy enclosure. |
Furnaces |
Model |
Range |
Stability |
Description/Features |
9150 Thermocouple Furnace |
150 °C to 1200 °C
302 °F to 2192 °F |
±0.5 °C |
Benchtop thermocouple furnace.
Interchangeable insert sleeves.
Fast heating and cooling. |
9112B Calibration Furnace |
300 °C to 1100 °C
572 °F to 2012 °F |
±0.1 °C |
Standard block fits five probes.
Accommodates long probes.
Gradients less than ±0.3 °C at 1000 °C. |