Temperature Calibration Services

photo-2r

American Fork, Utah lab 

Hart’s NVLAP accredited Metrology Laboratory (lab code 200348) in American Fork, Utah provides temperature calibrations from approximately –200 °C to 1000 °C using fixed-point and comparison methods. Our accredited uncertainties are among the lowest commercially available anywhere in the world. Our prices are very competitive and our turn-around times are excellent. Our reports are comprehensive and include as-found and as-left data as well as pass/fail criteria (where applicable) and a concise statement of the method used. Calibrations performed at Hart are traceable to NIST and meet the new ISO 17025 requirements as described in the following pages. 

For fixed-point calibrations, we use Hart fixed-point cells and apparatus, Hart SPRTs as check standards, and conventional DC bridges with DC standard resistors. Our fixed-point calibration procedures are based on CCT procedures, so you can be confident that the technique is current, correct, and thorough. 

For comparison calibrations, we use Hart baths, Hart SPRTs, and Hart readouts. We use several different techniques to minimize uncertainties while maximizing efficiency to keep the costs as low as possible without compromising quality. All Hart-manufactured instruments (except SPRTs and some thermocouples, which come uncalibrated) are certified before they are shipped to you. We don’t simply provide a “certificate of conformance” with a couple of NIST numbers like some other manufacturers and then sock you with a high fee if you require a proper calibration. We are the laboratory of choice for many of our customers because they know that they can depend on us for correct, complete, and on-time calibrations at reasonable prices. 

Norwich, England lab 

In 2003, after extensive planning and a significant capital investment, Hart Scientific opened a primary temperature calibration laboratory in Europe. This new lab in Norwich, England, will service the precision temperature calibration needs of customers in Europe, the Middle East, and Africa. The UK lab uses the same great Hart fixed point cells, furnaces, baths, and thermometers used in the American Fork, Utah lab. We even have similarly excellent metrology experts in this lab. Watch for us to also have UKAS accreditation here soon, with similar uncertainties to that of Hart’s American Fork, Utah lab! 

Calibration Ordering Information

SPRT calibration by ITS-90 fixed point           NVLAP accredited

All calibrations in this section include the following: (1) calibration at two levels of current and extrapolation to zero power, (2) ITS-90 deviation function coefficients and interpolation tables for the nominal current calibration and the zero-power calibration in W vs. T 90 , and (3) analysis for compliance to ITS-90 criteria for a standard interpolating instrument of the ITS-90. This represents our best measurement capability(BMC) for SPRTs. Recommended when you absolutely must have the best uncertainty possible. Only Excellent SPRTs qualify. 

Order No. 

Temperature 

ITS-90 Subranges 

Fixed Points Used 



Temperature 



Uncertainty 

–197 °C (LN2)

0.60 mK

–38.8344 °C (TPHg) 

0.35 mK

0.010 °C (TPW)

0.20 mK

29.7646 °C (MPGa)

0.35 mK

156.599 °C (FPIn)

0.70 mK

231.928 °C (FPSn)

0.90 mK

419.527 °C (FPZn)

1.2 mK

660.323 °C (FPAl)

2.0 mK

961.78 °C (FPAg) 8.0 mK

1910-4-7

–200 °C to 660 °C

4, 7

comp at NBPLN2, TPHg, TPW, FPSn, FPZn, FPAl 

1910-4-8

–200 °C to 420 °C

4, 8

comp at NBPLN2, TPHg, TPW, FPSn, FPZn 

1910-4-9

–200 °C to 232 °C

4, 9

comp at NBPLN2, TPHg, TPW, FPIn, FPSn 

1910-5-7

–40 °C to 660 °C

5, 7

TPHg, TPW, MPGa, FPSn, FPZn, FPAl 

1910-5-10

–40 °C to 157 °C

5, 10

TPHg, TPW, MPGa, FPIn 

1910-7

0 °C to 660 °C

7

TPW, FPSn, FPZn, FPAl 

1910-8

0 °C to 420 °C

8

TPW, FPSn, FPZn 

(back to top)

SPRT calibration by ITS-90 fixed point           NVLAP accredited

All calibrations in this section include the following: (1) calibration at two levels of current and extrapolation to zero power, (2) ITS-90 deviation function coefficients and interpolation tables for the nominal current calibration and the zero-power calibration W vs. T 90 , and (3) analysis for compliance to ITS-90 criteria for a standard interpolating instrument of the ITS-90. Recommended for working standard SPRTs, when slightly larger uncertainties are acceptable. 

Order No. 

Temperature

ITS-90 Subranges

Fixed Points Used



Temperature



Uncertainty

–197 °C (LN2) 

1.0 mK

–38.8344 °C (TPHg)

0.8 mK

0.010 °C (TPW)

0.5 mK

29.7646 °C (MPGa)

0.8 mK

156.599 °C (FPIn)

1.5 mK

231.928 °C (FPSn)

1.5 mK

419.527 °C (FPZn)

1.8 mK

660.323 °C (FPAl)

3.0 mK

1911-4-7 

–200 °C to 660 °C

4, 7

comp at NBPLN2, TPHg, TPW, FPSn, FPZn, FPAl 

1911-4-8 

–200 °C to 420 °C

4, 8

comp at NBPLN2, TPHg, TPW, FPSn, FPZn 

1911-4-9 

–200 °C to 232 °C

4, 9 

comp at NBPLN2, TPHg, TPW, FPIn, FPSn 

1911-5-7 

–40 °C to 660 °C

5, 7 

TPHg, TPW, MPGa, FPSn, FPZn, FPAl 

1911-5-10 

–40 °C to 157 °C

5, 10 

TPHg, TPW, MPGa, FPIn 

1911-7 

0 °C to 660 °C

TPW, FPSn, FPZn, FPAl 

1911-8 

0 °C to 420 °C

TPW, FPSn, FPZn 

(back to top)

SPRT calibration by ITS-90 fixed point          NVLAP accredited 

All calibrations in this section include the following: (1) ITS-90 deviation function coefficients and interpolation table for the nominal current calibration W vs. T 90 , and (2) analysis for compliance to ITS-90 criteria for a standard interpolating instrument of the ITS-90. This larger uncertainty SPRT calibration is still better than most offered in the industry, and is easier on the wallet. Recommended for any SPRT. 

Order No.


Temperature

ITS-90 Subranges


Fixed Points Used



Temperature



Uncertainty

–197 °C (LN2)

2.0 mK

–38.8344 °C (TPHg)

2.0 mK

0.010 °C (TPW)

2.0 mK

29.7646 °C (MPGa)

2.0 mK

156.599 °C (FPIn)

3.0 mK

231.928 °C (FPSn)

4.0 mK

419.527 °C (FPZn)

6.0 mK

660.323 °C (FPAl)

8.0 mK

1912-4-7

–200 °C to 660 °C

4, 7

comp at NBPLN2, TPHg, TPW, FPSn, FPZn, FPAl

1912-4-8

–200 °C to 420 °C

4, 8

comp at NBPLN2, TPHg, TPW, FPSn, FPZn

1912-4-9

–200 °C to 232 °C

4, 9

comp at NBPLN2, TPHg, TPW, FPIn, FPSn

1912-5-8

–40 °C to 420 °C

5, 8

TPHg, TPW, MPGa, FPSn, FPZn

1912-5-9

–40 °C to 232 °C

5, 9

TPHg, TPW, MPGa, FPIn, FPSn

1912-5-10

–40 °C to 157 °C

5, 10

TPHg, TPW, MPGa, FPIn

1912-7

0 °C to 660 °C

7

TPW, FPSn, FPZn, FPAl

1912-8

0 °C to 420 °C

8

TPW, FPSn, FPZn

(back to top)

Precision PRT calibration by ITS-90 fixed point    NVLAP accredited 

All calibrations in this section include the following: (1) ITS-90 deviation function coefficients and interpolation tables for the nominal current calibration in resistance vs. T90. Recommended for high quality, secondary standard PRTs only. Hart models 5626, 5628, and 5614 qualify. 

Order No.


Temperature

ITS-90 Subranges


Fixed Points Used
 



Temperature



Uncertainty

–197 °C (LN2)

6.0 mK 

–100 °C

10.0 mK

–38.8344 °C (TPHg)

6.0 mK

0.010 °C (TPW)

4.0 mK

156.599 °C (FPIn)

6.0 mK

231.928 °C (FPSn)

6.0 mK

419.527 °C (FPZn)

9.0 mK

660.323 °C (FPAl)

14.0 mK

1913-4-7

–200 °C to 660 °C

4, 7 

comp at NBPLN 2 , comp at –100 °, TPHg, TPW, FPIn, FPSn, FPZn, FPAl

1913-4-8

–200 °C to 420 °C

4, 8 

comp at NBPLN 2 , comp at –100 °, TPHg, TPW, FPIn, FPSn, FPZn

1913-4-9

–200 °C to 232 °C

4, 9 

comp at NBPLN 2 , TPHg, TPW, FPIn, FPSn

1913-5-8

–40 °C to 420 °C

5, 8 

TPHg, TPW, FPIn, FPSn, FPZn

1913-5-9

–40 °C to 232 °C

5, 9 

TPHg, TPW, FPIn, FPSn

1913-7

0 °C to 660 °C

TPW, FPIn, FPSn, FPZn, FPAl

1913-8

0 °C to 420 °C

TPW, FPIn, FPSn, FPZn

(back to top)

Precision PRT calibration by comparison            NVLAP accredited 

All calibrations in this section include the following: (1) ITS-90 deviation function coefficients, and (2) interpolation table in 1-degree increments in terms of resistance vs. T90. Recommended for high quality, secondary standard PRTs, where higher uncertainty is acceptable. Hart models 5626, 5628, 5612, 5613, and 5614 qualify. 

Order No. 

Temperature 

Comparison Points Used 



Temperature 


Uncertainty 
–200 °C  10 mK 
–100 to –50 °C  10 mK 
–50 to 0 °C  8 mK 
0.010 °C  6 mK 
0 to 200 °C  9 mK 
200 to 300 °C  12 mK 
300 to 400 °C  14 mK 
400 to 550 °C  16 mK 

1922-4-R 

–200 °C to 500 °C 

–197.0 °C, –100 °C, –38.8 °C, 0.01 °C, 156.6 °C, 231.9 °C, 419.5 °C, 500 °C 

1922-4-8 

–200 °C to 420 °C 

–197.0 °C, –100.0 °C, –38.8 °C, 0.01 °C, 156.6 °C, 231.9 °C, 419.5 °C 

1922-5-8 

–40 °C to 420 °C

–38.8 °C, 0.01 °C, 156.6 °C, 231.9 °C, 419.5 °C 

1922-5-9 

–40 °C to 232 °C

–38.8 °C, 0.01 °C, 156.6 °C, 231.9 °C 

1922-R 

0 °C to 500 °C

0.01 °C, 156.6 °C, 231.9 °C, 419.5 °C, 500 °C 

1922-8 

0 °C to 420 °C

0.01 °C, 156.6 °C, 231.9 °C, 419.5 °C 

(back to top)

PRT (RTD) calibration by comparison      NVLAP accredited 

All calibrations in this section include the following: (1) fitted results with an appropriate equation and (2) interpolation table in 1-degree increments in terms of resistance vs. T90. Recommended for all industrial level PRT (RTD) probes. Hart models 5627, 5622, and 5618A qualify. 

Order No. 

Temperature 

Comparison Points Used 



Temperature 



Uncertainty 

–200 °C 

25 mK 

–100 to –50 °C 

25 mK 

–50 to 0 °C 

25 mK 

0.010 °C 

25 mK 

0 to 200 °C 

25 mK 

200 to 300 °C 

25 mK 

300 to 400 °C 

40 mK 

400 to 550 °C 

50 mK 

1923-4-R 

–200 °C to 500 °C 

–197.0 °C, –100.0 °C, –38.8 °C, 0.01 °C, 156.6 °C, 231.9 °C, 419.5 °C, 500 °C 

1923-4-8 

–200 °C to 420 °C 

–197.0 °C, –100.0 °C, –38.8 °C, 0.01 °C, 156.6 °C, 231.9 °C, 419.5 °C 

1923-4-N 

–200 °C to 300 °C 

–197.0 °C, –100.0 °C, –38.8 °C, 0.01 °C, 156.6 °C, 231.9 °C, 300 °C 

1923-4-9 

–200 °C to 232 °C 

–197.0 °C, –100.0 °C, –38.8 °C, 0.01 °C, 156.6 °C, 231.9 °C 

1923-5-8 

–40 °C to 420 °C 

–38.8 °C, 0.01 °C, 156.6 °C, 231.9 °C, 419.5 °C 

1923-5-N 

–40 °C to 300 °C 

–38.8 °C, 0.01 °C, 156.6 °C, 231.9 °C, 300 °C 

1923-5-9 

–40 °C to 232 °C 

–38.8 °C, 0.01 °C, 156.6 °C, 231.9 °C 

1923-N 

0 °C to 300 °C 

0.01 °C, 156.6 °C, 231.9 °C, 300 °C 

1923-9 

 0 °C to 232 °C 

0.01 °C, 156.6 °C, 231.9 °C 

1923-10 

0 °C to 157 °C 

0.01 °C, 100 °C, 156.6 °C 

(back to top)

Precision thermistor calibration by comparison     NVLAP accredited 

All calibrations in this section include the following: (1) polynomial solution with coefficients in Steinhart-Hart or third order, and (2) bound interpolation table in 0.01- or 0.1-degree increments (depending upon span of calibration) in terms of resistance vs. T90. Order the 1925-A for secondary thermistors with 100 °C range, like the Hart 5610 & 5611 probes. The 1925-B&C calibrations are recommended for very high accuracy thermistor standards like the Hart 5640-44 series probes. 

Order No. 

Temperature 

Comparison Points Used 

Uncertainty (k=2) 

1925-A 

100 °C span 

6 points over span 

10 mK 

1925-B 

60 °C span 

7 points over span 

1.5 mK 

1925-C 

100 °C span 

11 points over span 

2.5 mK 

1925-D 

10 °C span 

4 points over span 

<10 mK 

(back to top)

Noble-metal thermocouple calibration by ITS-90 fixed point      NVLAP accredited 

All calibrations in this section include the following: (1) ITS-90 polynomial coefficients in accordance with NIST Monograph 175, and (2) bound interpolation table in 1-degree increments in terms of EMF vs. T90. Recommended for high quality thermocouple standards. Order 1918-A for Au/Pt thermocouple standards, 1918-B for Type S and Type R standards. 

Order No. 

Temperature 

Fixed Points Used 

Uncertainty (k=2) 

Extrapolated Uncertainty (k=2) 

1918-A 

0 °C to 1000 °C 

FPSn, FPZn, FPAl, FPAg    (Gold/pt) 

0.02 °C 

0.025 °C 

1918-B 

0 °C to 1450 °C 

FPSn, FPZn, FPAl, FPAg    (Type S–R) 

0.15 °C 

2 °C 

Requirements for thermocouples:  Must have very clean, unbroken (even uncracked) sheaths, have at least 20” long sheath length, and have at least 36” lead length. Please call our customer service department for clarification if needed. 

(back to top)

Precision Digital Thermometer System Calibration by Comparison     NVLAP Accredited 

All calibrations in this section include as-found data, as-left system data, and adjustments. Systems are calibrated as systems and not as individual components (probe and readout). Uncertainties are similar to those listed on the opposite page, depending on the system being calibrated. Consult Hart's customer service group for temperature ranges not listed here. An additional fee is charged for non-standard temperature points requested. 

Order No. 

Temperature 

Comparison Points Used 

1930-4-R 

–200°C to 500°C 

–197.0°C, –38.8°C, 0.01°C, 231.9°C, 419.5°C, 500.0°C 

1930-4-8 

–200°C to 420°C 

–197.0°C, –38.8°C, 0.01°C, 231.9°C, 419.5°C 

1930-D-8 

–100°C to 420°C 

–100.0°C, –38.8°C, 0.01°C, 231.9°C, 419.5°C 

1930-5-8 

–40°C to 420°C 

–38.8°C, 0.01°C, 231.9°C, 419.5°C 

1930-5-9 

–40°C to 232°C 

–38.8°C, 0.01°C, 156.6°C, 231.9°C 

1930-8 

0°C to 420°C 

0.01°C, 231.9°C, 419.5°C 

1935-A 

100°C span 

6 points over span 

1935-B 

60°C span 

7 points over span 

1935-C 

100°C span 

11 points over span 

(back to top)

Fixed Point Cell Direct Comparison      NVLAP Accredited 

Comparison to a Hart working standard fixed-point cell.  A comprehensive calibration report is included. (For Best Measurement Capability comparisons, please call Hart.) 

Order No.

ITS-90 Fixed Point Cell

Uncertainty (k=2)

1904-Hg 

TPHg 

0.25mK 

1904-Tpw 

TPW 

0.10mK 

1904-Ga 

MPGa 

0.10mK 

1904-In 

FPIn 

0.70mK 

1904-Sn 

FPSn 

0.80mK 

1904-Zn 

FPZn 

1.00mK 

1904-Al 

FPAl 

1.80mK 

1904-Ag 

FPAg 

4.50mK 

(back to top)

DC Resistance Calibration      NVLAP Accredited 

Your DC resistors are compared to Hart’s standard resistors.  A comprehensive calibration report is included. 

Order No.

Resistance Range

Uncertainty (k=2)

1960 

1 - 10 Ohm 

0.35 ppm 

1960 

10 - 100 Ohm 

0.45 ppm 

1960 

100 - 1000 Ohm 

0.60 ppm 

1960 

1000 - 10000 Ohm 

0.70 ppm 

(back to top)

Humidity Sensor Calibration 

All calibrations in this section are traceable to NIST and include certificates compliant with ANSI/NCSL Z540-1 and ISO Guide 17025. As-found data, as-left data, and adjustments are included. 

Order No. 

Temp. Points 

RH Points 

1980-A 

      3 

1980-B 

      5 

1980-C 

      5 

1980-D 

      5 

(back to top)

Instrument Calibration 

For recalibration of Hart Scientific thermometer readouts and dry-wells please call Hart Customer service. If you are calling from within the USA, please call toll free (800) 438-4278 or (888) 538-4278.  If you are calling from outside of the USA please call (801) 763-1600. Calibration of Hart thermometer readouts fall within Hart’s scope of accreditation. 